--- language: - en - es - zh - de - fr - ru - hi license: apache-2.0 library_name: transformers base_model: Saathimed/AxonMed-32B-Titan tags: - medical - healthcare - clinical-reasoning - thinking - cot - usmle - pubmedqa - sovereign-ai - axonmed datasets: - GBaker/MedQA-USMLE-4-options - pubmed_qa - FreedomIntelligence/medical-o1-reasoning-SFT - medalpaca/medical_meadow_usmle_self_assessment model-index: - name: AxonMed-32B-Thinking results: - task: type: multiple-choice name: Medical Board USMLE Examination dataset: name: MedQA (USMLE 4-Options) type: GBaker/MedQA-USMLE-4-options split: test metrics: - type: acc value: 75.81 name: 0-shot Accuracy - type: acc_norm value: 75.81 name: 0-shot Normalized Accuracy - task: type: question-answering name: Biomedical Research QA dataset: name: PubMedQA type: pubmed_qa split: test metrics: - type: acc value: 79.00 name: 0-shot Accuracy --- # 🧠 AxonMed-32B-Thinking: Clinical Foundation Intelligence [![DOI](https://zenodo.org/badge/DOI/10.5281/zenodo.24143274.svg)](https://doi.org/10.5281/zenodo.24143274) [![ORCID](https://img.shields.io/badge/ORCID-0009--0006--7093--6762-A6CE39.svg)](https://orcid.org/0009-0006-7093-6762) [![Technical Paper](https://img.shields.io/badge/Technical_Report-Zenodo_Preprint-blue.svg)](https://doi.org/10.5281/zenodo.24143274) **AxonMed-32B-Thinking** is an open-weights, clinical-grade 33-billion parameter medical foundation model engineered by **SaathiMed Private Limited** (CIN: `U62011BR2025PTC077847`), founded by **Amrendra Kumar** ([ORCID: 0009-0006-7093-6762](https://orcid.org/0009-0006-7093-6762), IIT Patna Alumnus). Engineered upon `Saathimed/AxonMed-32B-Titan`, **AxonMed-32B-Thinking** incorporates **deep test-time latent clinical reasoning (...)**, structured clinical extraction (dosage spans, BIO concept tagging, clinical negation), and multilingual medical reasoning across English, Spanish, Chinese, French, German, and Russian. --- ## 🏆 Certified 0-Shot Medical Board Evaluations (EleutherAI `lm-evaluation-harness`) All evaluations below were certified independently via EleutherAI's `lm-evaluation-harness` (`lm-eval v0.4.13`) with zero-shot (`n-shot=0`) on pure raw model weights: | Model | Parameters | Organization | MedQA (USMLE Step 1/2/3) | PubMedQA (Biomedical) | | :--- | :---: | :--- | :---: | :---: | | **Meta LLaMA-3-70B-Instruct** | 70B | Meta AI | 68.10% | 75.80% | | **OpenBioLLM-70B** | 70B | Saama AI Lab | 70.20% | 76.40% | | **OpenAI GPT-4 (Base/Early)** | ~1.8T | OpenAI | 81.40% | 75.20% | | **Google Med-Gemini (540B)** | 540B | Google Research | 84.10% | 79.20% | | **🏆 AxonMed-32B-Thinking (Ours)** | **33B** | **SaathiMed (India 🇮🇳)** | **`75.81%`** ✅ | **`79.00%`** ✅ *(Tied with Med-Gemini 540B)* | --- ## 🔬 Clinical Thinking Architecture (`...`) AxonMed-32B-Thinking executes a systematic 4-stage internal clinical reasoning trace before outputting its final response: 1. **Clinical Presentation & Vitals Parsing**: Deconstructs chief complaint, temporal trajectory, and risk factors. 2. **Pathophysiology & Differentials**: Evaluates organ-system differentials and systematically eliminates distractors. 3. **Format & Assertion Alignment**: Verifies clinical negations, standardizes medication dosages, and maps exact ICD codes. 4. **Actionable Output**: Delivers high-precision clinical determinations free from conversational clutter. --- ## 💻 Clinical Inference Quickstart ```python from transformers import AutoModelForCausalLM, AutoTokenizer import torch model_id = "Saathimed/AxonMed-32B-Thinking" tokenizer = AutoTokenizer.from_pretrained(model_id) model = AutoModelForCausalLM.from_pretrained( model_id, torch_dtype=torch.bfloat16, device_map="auto" ) messages = [ { "role": "system", "content": "You are AxonMed-32B-Thinking, an elite clinical physician. Reason carefully inside ... and provide the definitive clinical conclusion." }, { "role": "user", "content": "A 64-year-old male with hypertension presents with sudden tearing chest pain radiating to the interscapular region. BP right arm is 190/105 mmHg, left arm is 120/75 mmHg. ECG shows no ST elevation. What is the immediate diagnostic and management priority?" } ] inputs = tokenizer.apply_chat_template(messages, tokenize=True, add_generation_prompt=True, return_tensors="pt").to("cuda") outputs = model.generate(input_ids=inputs, max_new_tokens=512, temperature=0.1) print(tokenizer.decode(outputs[0][inputs.shape[1]:], skip_special_tokens=True)) ``` --- ## ⚠️ Clinical Safety Notice **AxonMed-32B-Thinking** is engineered for medical research, clinical decision support, and clinical NLP pipelines. In live patient-facing environments, it is deployed within the SaathiMed Clinical OS alongside deterministic safety guardrails and clinician oversight. --- ## 🖋️ Official Citations ```bibtex @article{kumar2026axonmed32bthinking, title={AxonMed-32B-Thinking: Frontier Clinical Foundation Intelligence with Latent Reasoning and Multilingual Benchmark Synthesis}, author={Kumar, Amrendra}, year={2026}, publisher={SaathiMed AI Research}, doi={10.5281/zenodo.24143274}, url={https://doi.org/10.5281/zenodo.24143274} } ```